Carrier 48fc 15 ton.

Carrier roof curbs that were installed back to 1989, which makes replace-ment easy and eliminates the need for curb adapters or changing utility connections. Single-stage units deliver SEERs up to 14.3. IEERs up to 15.0 and heating HSPFs up to 8.2. All models are capable of either vertical or horizontal airflow.

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit; Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drainWe would like to show you a description here but the site won’t allow us.3 to 12.5 Nominal Tons. Exclusive, new EcoBlue™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The …Carrier15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. ... 48fc-16-01si; Specifications. Brand Carrier; Availability Available for ...

Carrier 48TCED Manuals | ManualsLib. Check Details. Carrier 58UHV Product data | Manualzz. Check Details. carrier chiller data. Check Details. WeatherMaker® 48FC Single-Packaged Rooftop Units with EcoBlue™ Technology. Check Details. Carrier 14 Seer Air Conditioner - 2 Ton 14 Seer Icp Carrier Grandaire. Check …© 2021 Carrier Form 48FCG-4-6-01PD 48FCG*04, 05, 06 48FCG: Single-Package Ultra Low NOx Gas Heating/Electric Cooling Rooftop Units with Puron® Refrigerant (R-410A) …

New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit.

04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel ExchangerSEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain.We would like to show you a description here but the site won’t allow us.View and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with R-410A …This Comfort system offers that perfect balance between budget limits you may have today and your desire for long-term energy savings. It wraps together the summer comfort of an air conditioner with winter warmth from a gas furnace with a durable stainless steel heat exchanger. It also comes with a louvered hail guard for enhanced coil protection.

1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. All 48FC units comply with ASHRAE 90.1-2016 Energy Standard. 4. 48FC units comply with US Energy Policy Act (2005).

15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48fc-16-01si; Specifications. Brand Carrier; Availability Available ...

Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting (144 pages) Single package rooftop units with systemvu controls version 1.x and puronr (r-410a) refrigerant. Table of Contents General. Manual is suitable for 4 more products: 48GC Series 48GC 05 48GC 04 48GC 06. Brand: Carrier | Category: Air Conditioner | Size: 4.05 MB.Are you in the market for a half ton towable fifth wheel? If so, you’re in luck. There are plenty of great options out there to choose from. But with so many different models and f... 15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48fc-16-01si; Specifications. Brand Carrier; Availability Available ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 70 FAN PERFORMANCE (cont.) Table 57 – 48TC**16 3 PHASE 15 TON HORIZONTAL SUPPLY Available External Static Pressure ...The Carrier rooftop unit (RTU) was designed by customers for customers. With "no-strip" screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton WeatherMaker Carrier rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. Value-added features include:

When it comes to finding the perfect fifth wheel for your needs, there are a few key factors to consider. Fifth wheels are a great option for those who want to enjoy the comforts o...7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU 48TCEM08A2A5-0A0A0. ... Brand Carrier; BTU Input 224000; Equipment Type Commercial Packaged Outdoor Unit; Fan Type Centrifugal; Frame Size 56; Gas Stages 2-Stage; Heat Size Medium Gas Heat; LEER 12.7;Same footprint as installed Carrier 3-12.5 ton rooftops back to 1989, reducing installation costs and time; Field convertible from vertical to horizontal airflow for slab mounting (sizes 04-16) Provisions for thru-the-bottom power entry capability as standard; Dedicated vertical and horizontal airflow models available (sizes 17 to 30 only)Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 70 FAN PERFORMANCE (cont.) Table 57 – 48TC**16 3 PHASE 15 TON HORIZONTAL SUPPLY Available External Static Pressure ...48TCED14A2A6-0A0A048 = Gas Heat Packaged RooftopTC = WeatherMaker™ Standard EfficiencyE = Medium HeatD = Two Stage Cooling Models 08-1614 = 12.5 tonsA = None2 = Belt Drive, Medium Static OptionA = Al/Cu - Al/Cu6 = …

Documents Details. WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology. 48FC. Type: Gas heat. Capacity Range (Tons): 3 - 27.5. Efficiency …

Orissa Bengal Carrier News: This is the News-site for the company Orissa Bengal Carrier on Markets Insider Indices Commodities Currencies StocksWhen it comes to finding the perfect fifth wheel for your needs, there are a few key factors to consider. Fifth wheels are a great option for those who want to enjoy the comforts o...Air Conditioner Carrier 48FC Installation Instructions Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) Air Conditioner Carrier 48HC 04-28 ManualThere are already plenty of monopolies in big tech. Google isn't alone....GOOGL Alphabet Inc. (GOOGL) and its Google are playing scapegoat this Sunday. The tech giant is expect...Carrier delivers efficient, dependable performance, inside and out. With Carrier split systems, a wide range of outdoor air conditioners and heat pumps works seamlessly with innovative indoor air handlers to create reliable solutions that are easy-to-install and service for a wide range of commercial HVAC needs. 10 Product (s)View and Download Carrier 48HC*04–14 service and maintenance instructions online. Nominal 3 to 12.5 Tons With Puron (R410A) Refrigerant. 48HC*04–14 air conditioner pdf manual download. ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge ...Carrier

Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat

Carrier’s new Gas Heat/ Electric Cooling WeatherExpert® 6 to 10 ton commercial packaged rooftop models are designed to provide total low cost of ownership by providing some of the highest cooling efficiencies in the industry, with low installed costs, low maintenance costs, and high reliability. These models focus on providing high

Carrier Puerto Rico - Air ConditioningCE - Carrier EnterpriseCarrier® WeatherMaker® - 4 Ton 14 SEER Packaged Rooftop Gas Heat & Electric Cool Unit (208/230-3-60) ... IEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. ... 48FC Prop 65 Yes Refrigerant ...CE - carrierenterprise.comIf you’re searching for a furnace to complete your HVAC system, Carrier’s offerings should be a great fit. Here’s what to expect from Carrier furnace costs. Expert Advice On Improv...Gas Heating/Electric Cooling Models (48FC) 1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3.Drawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. DXF/CAD templates are full scale 2D drawings of Carrier products. Layers are used to separate unit outlines, clearances, dimensions, and connections. Drawings are provided in AutoCAD® 1 DXF format (Drawing Interchange Format ...48FCFM16A3A5-0A0A0. 48FC = Gas Heat Packaged Rooftop. F = High Heat. M = Single Circuit, Two Stage Cooling Model. 16 = 15 Tons. A = No Smoke or CO 2 sensor. 3 = Direct Drive, Eco Blue, High Static Option. A = Al/Cu - Al/Cu. 5 = 208/230-3-60. 12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM14A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...

Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: Single cooling stage models are available from 3 -- 10 ton. Two cooling stage models are available from 7.5 -- 15 ton. SEER up to 13.0. (up to 13.4 with ECM motor) EER's up to 11.1. (up to 11.4 with ECM motor) Replacement for. 48TCED08A2A6-0A0G0 - Gas Heat/Electric Cool Rooftop, 2-Stg 7.5T 460-3-60 Medium Fan; 48TCEM08A2A6-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTUNew direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit.Instagram:https://instagram. brownfield obituariescsi group law firmindian grocery store in allentown padreamlight valley the spirits of nature CE - Carrier EnterprisePerformance Features. ASHRAE 90.1 and Energy Star compliant. Up to 15.6 SEER, 13.0 IEER, and 12.2 EER. Standard cooling operating range up to 125 °F (52°C) and down to 35°F (2°C). Low ambient controllers can bring cooling operation down to -20°F (-29°C) Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 ... ronnie shacklett wikipediabest seats at snapdragon stadium for monster jam 48VG. Gas heating and electric cooling with up to 16 SEER2 for enhanced energy savings with enhanced comfort features. Ultra-low NOx models available for California. 4.7 out of 5 stars. 45 Reviews. 5 Star. 80%. 4 Star. 13%. how to look up remington serial numbers 50FCQ 04 -28, 50GCQ 04-06 Single Package Rooftop Heat Pump Units with SystemVuTM Controls Version 3.X and Puron R-410A Refrigerant Controls, Start-Up, Operation and Troubleshooting Instructions IMPORTANT: This literature covers 50FCQ 04 -28 and 50GCQ 04-06 models with SystemVu controls version 3.X...Full-scale Carrier quality for a variety of equipment types. DXF/CAD templates are full scale 2D drawings of Carrier products. Drawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. ... 3-28 Ton Rooftop Units – 48/50TC(Q), 48/50KC(Q), 48/50HC(Q), 48/50LC, EnergyX® models. 48 ...Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6+ ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. 48GC units generally comply with ASHRAE 90.1-2016 Energy Standard. Please review size specific data for compliance. 4.